“pH and Acid Titration”
W.C. PAETZ - January 21, 2004 Michigan State University
Abstract:
During our lab exercise we followed the protocol for discerning accurate
measures for pH and titratable acidity for six different wines. As a prelude
to this analysis the calibration of the equipment and staging of samples
was carried out to facilitate consistent and expedient laboratory results.
INTRODUCTION:
A comprehensive program for grape and wine analysis includes several critical
metrics. Being able to discern the pH and titratable acidity are essential
skills. These factors come in to play at every stage of wine production
from harvest, as juice or must, after primary fermentation, during problem
solving, prior to and during aging and finishing and especially prior
to bottling.
For the enologist to safely and to effectively produce accurate results,
they must be familiar with the equipment and the tests.
With regard to pH, this factor must be known to control wine quality,
to avoid spoilage and to strategically use chemicals and acids to protect
the final product.
With regard to titratable acidity, “(1.) Fruit, including grapes,
contain different types of acids. Too much acid renders a wine undrinkable.
On the other hand, if wine does not have enough acidity, the result is
flat or insipid tasting wine. That’s why it is important to check
the acid levels and adjust if necessary.”
“(2.) There are two ways to measure an acid. They are by titration
for total titratable acid and by measuring pH. One of the hardest things
to understand is that they do not measure the same thing and do not correlate
with one another. In my mind if they both measure acid, one should be
able to convert one to the other but it just doesn’t work that way.”
“(2.)Acids are molecules and they must be made up of at least two
atoms. At least one of those atoms must be hydrogen. This hydrogen ion
is the magic part of acid, has a positive charge and is written [H+].”
Titration measures the total [H+] ion concentration, the ones floating
around in solution, plus the ones still holding on to their constituents.
The pH measures only the ones that are dissociated and floating around
in the solution. Titration measures how many could react. The pH measures
how many are ready to react.”
“(3.) Like a lot of other things in life, pH is what you make of
it. It is easy to learn to use pH, and you don’t really need to
understand it. Most of us don’t understand the cars we drive or
the TV sets we so blithely manipulate. Start by recognizing pH as a very
important number that can help you make better wines.”
Total titratable acidity is not a measure of total acid, but of the acid
that is available to react with the NaOH solution with which we titrate,
pH is a measure of the acid strength in the must or wine. It is the pH,
rather than the total acidity, which indicates the ability of the must
to resist oxidation and invasion by bacteria, and which determines how
much SO2 is needed.
These are some of the reasons that support this study.
Materials and Methods
Titratable Acidity:
Equipment:
1.) 250 ml Erlenmeyer flasks
2.) 10 ml Volumetric A Pipet
3.) Titration assembly (burette set up)
4.) 0.1N Sodium Hydroxide
5.) pH meter
6.) Wine Samples
7.) magnetic stirring bar 3/8
8.) distilled water
Method:
1.) Standardize pH meter.
2.) Fill burette with 0.1 N NaOH.
3.) Add distilled water to ensure pH meter covered.
4.) Rinse pH electrode with a few ml of distilled water.
5.) Place in wine sample
6.) Position burette so outlet is above beaker.
7.) Place and activate stir bar.
8.) Tartrate the pH of sample to 8.2
9.) Read measure of NaOH and record this volume.
10.) Multiply by .75 Titre value.
“pH Measurement of Wine Sample”
Equipment:
1.) Corning Scholar 425 pH meter
2.) Beakers with various samples
3.) Distilled water
4.) Wipes to dry electrode probe.
5.) 3/8 magnetic stir bar
Method:
1.) Standardize the pH meter.
2.) Place stir bar.
3.) Immerse the electrode into wine sample beaker.
4.) Slowly activate stir bar in sample beaker
5.) Take reading of stabilized pH from meter and record.
6.) Rinse and wipe electrode and place in storage solution while preparing
next sample for analysis.
Results
(Figure 1)
Cultivar pH TA
Carbonic Maceration Foch 2.95 9.6
Delaware 3.02 7.6
N.W. Vignoles 3.36 12.4
Sparkling Foch 2.91 12.4
Late Harvest Vignoles 3.12 14.9
Frontenac Juice 3.03 18.5
Discussion
There is a need to exercise caution when using a pH meter as pH is exponential
and quickly moves from pH 7 to pH 8. The use of this equipment when analyzing
red wines is critical as the ability to discern the end point when using
Phenolphthalein or another color indicator is quite problematic.
According to Jackson, (5.) “A pH range of 3.1 – 3.4 is the
goal for white wines and 3.3 to 3.6 for most red wines.”
Conclusion
This study was not only worth while but extremely important. A person
can not consistently make desirable wines with out a profound understanding
of these analytical tests and ensuing results. One needs to be able to
confidently follow the test procedure and know what the results mean in
terms of the status of the wine and what desirable metrics should be aspired
to as well as what action needs to be taken to correct and protect the
wine.
Appendix
Refer to figure 1 in text.
References:
1.) Martin Jordan, Host of Video, 1995 “Making Wine”, The
comprehensive how to video for making wine in your home. Bacchus Productions
Inc.Toronto, Ontario
2.) Acid Titration, G. Goodwine , http://www.geocities.com/medievalbrewers/acid.html
3.) J.E. Underhill, pH Without Pain, The Grapevine a news letter for winemakers
in British Columbia.
http://www.bcawa.ca/winemaking/ph.htm
4.) R.S. Jackson, Wine Science Principles Practice Perception, Cool Climate
Oenology and Viticulture Institute, Ontario Canada. (2000), Page 240
Back to MSU Page for